? | ||
產(chǎn)品介紹: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
產(chǎn)品規(guī)格: | 產(chǎn)品品牌: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
參考價格:: | ¥ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
詳細(xì)說明: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
LAL(內(nèi)毒素)檢測附屬產(chǎn)品(Accessory Products)
內(nèi)毒素標(biāo)準(zhǔn)品 - Endotoxin (E. coli) StandardsEndotoxin (E. coli) Challenge VialsMgCl2, 10mM SolutionTris Buffer, 50 mM SolutionLAL Reagent WaterPyrogen-free test tubesEppendorf? BioPur Pipette TipsLAL Reagent Grade Multi-well Plates?-Glucan BlockerPyrosperse? Dispersing AgentStepped Neutral Density PlateGround aluminum block, with lidReagent ReservoirSample Container, Depyrogenated
Control Standard Endotoxin is referenced against the USP Reference Standard Endotoxin following the procedures set forth in the "Guideline on Validation of the Limulus Amebocyte Lysate Test as an End-Product Endotoxin Test for Human and Animal Parenteral Drugs, Biological Products and Medical Devices".
N186 is intended for use as the control standard endotoxin in PYROGENT? Gel Clot assays. N185 contains high potency endotoxin and is intended for use in endotoxin removal system challenges, i.e. depyrogenation ovens, and other spiking studies. E50-640 is intended for use with QCL-1000? assays and contains E. coli strain 0111:B4.
內(nèi)毒素挑戰(zhàn)管 -
For use in oven validation studies, contains >1000 EU/vial. The vials may be tested using any of our endotoxin detection kits.
氯化鎂溶液 -
MgCl2 should be used as the sample diluent when attempting to overcome inhibitory chelation effect. Examples of samples which chelate divalent cations include heparin and EDTA. MgCl2 may be used to prepare samples for any LAL assay. Contains <0.005 EU/ml endotoxin.
Tris緩沖液 -
Tris buffer is to be used in place of water as the sample diluent for highly acidic or basic samples (samples and sample dilutions should be between pH 6-8). Tris buffer may be used to prepare samples for any of our endotoxin detection assays. Contains <0.005 EU/ml endotoxin.
Storage: 2°C - 30°C
LAL反應(yīng)水 -
Recommended for reconstituting LAL reagents and the dilution of control standard endotoxin and test samples for endotoxin testing. Contains <0.005 EU/ml endotoxin.
無熱源檢測管 -
All test tubes are made from USP Type 1 flint borosilicate glass. Contain less than 0.005 EU/ml endotoxin.
Product number N207 is recommended for dilution of endotoxin standards and test samples for all endotoxin detection assays. Product numbers N201 and N205 are recommended for use as reaction tubes in gel clot assays.
Eppendorf?槍頭 -
These tips are to be used when testing with any of our LAL systems. The tips are certified to contain <0.001 EU/ml endotoxin. The new design of the tips allows more flexibility with different pipettors.
LAL反應(yīng)多孔板 -
These 96-well plates can be used with the QCL-1000? Chromogenic Endpoint Assay, Kinetic-QCL? Kinetic Chromogenic and PYROGENT-5000? Kinetic Turbidimetric LAL assays. The plates are certified to contain <0.0005 EU/well endotoxin. Each case contains 50 individually wrapped plates.
?-葡聚糖阻滯液 -
?-1,3-Glucans can produce false positive results in LAL assays. Some examples of glucan sources include yeast and cellulosic materials including hemodialysis filters. Our ?-G-Blocker may be used with any of our LAL assays. Note: PYROGENT? Gel Clot lysate products typically do not require ?-glucan blocker.
分散劑 -
Pyrosperse? helps eliminate endotoxin binding or masking in some samples, solving problems of inhibitory behavior. Examples of samples that may show endotoxin binding behavior include plasma protein fractions, electrolyte solutions, and lipid emulsions. Pyrosperse may be used with any of our LAL Kits.
板 -
For Elx808LBS and KQCL readers. The stepped neutral density plate is used for optical density validation of the reader and may be used with WinKQCL? Software.
帶蓋鋁塊 -
試劑儲存容器 -
無熱原樣本儲存容器 -
A 10 ml screw cap vial for transporting product samples for endotoxin analysis or sample storage.
|
購買進(jìn)口儀器、試劑和耗材——就在始于2001年的畢特博生物
m.kjhfd.cn |
|